Close fuel shut-off valve.
Loosen and unscrew hexagonal nut 1.
Remove fuel strainer cover 2 (cover and strainer,
one unit).
Clean fuel strainer 2 with diesel fuel. Replace if
necessary.
Place seal 3 in position.
Mount fuel strainer cover 2.
Tighten hexagonal screw 1.
Check for leaks.
6.2.3 Clean Strainer of Fuel Filter
Keep naked flames away when work-
ing on the fuel system. Do not
smoke!
Service and Maintenance 6.2 Fuel System
!
Close fuel shut-off valve.
Disconnect rubber hoses 3 from injection valves.
Disconnect rubber hose 1 from fuel tank.
Disconnect rubber hoses 4, 3 and 1 from unions
2 and dispose of in an environmentally friendly
manner.
C
onnect new rubber hoses 4, 3 and 1 to unions 2
.
Connect rubber hoses 3 to injection valves.
Connect rubber hose 1 to fuel tank.
Open fuel shut-off valve.
Check for leaks after start-up.
6.2.4 Change Fuel Leakage Line