Service Training
Page 4.2
Section 63
09.04
A B
Δp = 0 - 0,5 bar.
Δp = 0 - 0,5 bar.
Slowly depress the F and R accelerator pedals and determine Δp at start of
control (start of wheel rotation).
Δp at start of control
= 4
+ 0,5
bar.
noyes
yes
no
yes no
See "Hydrostatic travel
drive".
Remove adapter III at ports YF and ZF and install LP gauge with adapter II at
ports YF and ZF. Repeat the test.
Adjust Δp by turning
rear (looking in
direction of travel)
bushing or renew
travel control unit.
Fully depress the F and R accelerator pedals consecutively and determine Δp.
Δp = 11
+ 0,1
bar.
yes
no
C
D
Adjust start of control, see "Primary
adjustment of start of control".